Testing ability
1. Type test and factory test can be carried out according to the requirements of GB3216-89, and the testing accuracy reaches B level.
2. Factory field test capability
Flow rate: 15000m3/h head: 10Mpa, maximum power: 2000KW
3. Test capability on site
Flow measurement: ultrasonic flow meter, the maximum diameter of 2200 mm.
Lift test: 0.5 stage pressure sensor.
Power test: ammeter.